Cttsbd
WebSep 15, 2024 · CTTSBD. Performs data set stacking in batch mode. CTTSCA. Detects data set contentions. CTTSTK. Builds and updates the Stacking Database. CTTSTKR. … WebData sets written by the CTTSBD utility are not stacked by the Control-M/Tape Dynamic Dataset Stacking facility. DO STACK, DO STKRULE and DO STKGROUP statements in relevant Control-M/Tape rules are ignored by the CTTSBD utility. Use the CTTSBD utility to implement data set grouping similar to the grouping produced by DO STKGROUP …
Cttsbd
Did you know?
Web(These data sets may have been created by a previous run of the CTTSBD utility.) No prefix is added to output data set names for group NEW. The CTTSBD utility selects all data sets from group ACCT and group NEW. The following output data sets are created by this run of the CTTSBD utility: Table 368 CTTSBD Data Sets WebSep 15, 2024 · The CTTSBD utility searches the Media database for data sets and volumes that satisfy selection criteria specified in INCLUDE / EXCLUDE statements. Selected …
WebIf an input data set was uncataloged and failure occurred before the corresponding output data set was cataloged, the CTTSBD utility attempts to recatalog the input data set during the recovery process. Note: The CTTSBD utility attempts to recatalog a data set only once. If the recatalog attempt fails, the data set has to be recataloged manually. WebCTTSBD utility enters endless loop: PDF: Technical Bulletin 15-Nov-2024: Alerts INCONTROL customers to necessary 2024 year-end procedures. PDF: 24-Feb-2024: BMC is notifying users of an extension of the period of full support for Control-M versions 9.0.19 and 9.0.20. PDF: 17-Dec-2024:
WebMask characters are supported for many of the parameters of the CTTSBD utility. The ability to use mask characters is indicated in the description of the relevant parameters. The following mask characters can be used: Table 369 CTTSBD Masks. Mask. Description? Represents any one character * Webwhere jobname is the name of the job or started task that is executing the CTTSBD utility. When the above STOP command is issued, the CTTSBD utility acknowledges this fact (using an operator message) and continues processing the remaining data sets in the current input volume chain.
WebAug 20, 2006 · Posted: Fri Sep 01, 2006 8:51 pm. Reason : Specification exception. Usually caused by incorrect boundary. Read the description for pausible causes. Description : …
WebOUTUNIT – Unit name to be used by the CTTSBD utility for allocation of each output data set in this group. A name of up to eight characters can be specified. If a value is specified for OUTUNIT in the group definition, that value overrides the OUTUNIT name specified in the TYPERUN statement of the CTTSBD utility. DATASET c and o towpath snow clearanceWebThe CTTSBD utility can be run in simulation mode. This mode can be used to experiment with various stacking configurations (meaning, data set group definitions) without effecting data set location in the tape library. In simulation mode, the CTTSBD utility calculates output volume capacity according to the value specified for the OUTVOLMB ... can d.o.\u0027s perform surgeryWebCTTSBD utility enters endless loop: PDF: Technical Bulletin 15-Nov-2024: Alerts INCONTROL customers to necessary 2024 year-end procedures. PDF: 24-Feb-2024: BMC is notifying users of an extension of the period of full support for Control-M versions 9.0.19 and 9.0.20. PDF: 17-Dec-2024 can double glazed units be repairedWebHas anyone had experience with CTTSBD utility of CONTROL-M/T to copy volumes (not stacking just copy one to one) and willing to share his/her experience? Thanks, Arye Shemer-----For IBM-MAIN subscribe / signoff / archive access instructions, send email to ***@bama.ua.edu with the message: GET IBM-MAIN INFO ... fish tacos with best fish taco saucecan double glazed units be resealedWebHas anyone had experience with CTTSBD utility of CONTROL-M/T to copy volumes (not stacking just copy one to one) and willing to share his/her experience? Thanks, Arye … can double decker buses go on motorwayWebA value from 0 through 9999 can be specified. Default: No time limit. If the specified time limit is reached, the CTTSBD utility finishes processing the data sets in the current input volume chain before stopping. INUNIT — Unit name or unit address to be used by the CTTSBD utility for allocation of each input data set. can double hung windows be repaired